A nonpermeable, nonstructural rigid polyisocyanurate insulation sheathing board with high thermal resistance properties. Constructed from closed cell polyisocyan urate foam core, which is bonded on each side to an aluminum foil facer.

DESCRIPTION

APPLICATIONS FOR NEW / RETROFIT CONSTRUCTION

• Polyiso has the highest R-value per inch of any rigid foam board insulation. Increased thermal resistance improves wall energy efficiency performance. • Effective strategy to reduce initial construction costs. The higher thermal values per inch of Enerfoil insulation sheathing means that it requires less space than less efficient insulation to deliver the same level of performance. • User-friendly. Laminated foil facers on both sides of the sheathing provide moderate abuse-resistance on the job site. Enerfoil is lightweight and easy to cut, thus reducing labor costs on-site. Stud and fastener line indicators improve accuracy of installation. Provides versatility . Foil facers provide the long-term moisture resistance necessary for various wall applications. Enerfoil’s facers are also compatible with most solvent-based materials. • Has a uniform thickness for consistently maintaining air space requirements in cavity wall applications. • Available in 4' x 8' boards with the following thicknesses: 0.5” (12 mm), 0.625” (16 mm), 0.75” (18 mm), 1” (25 mm), 1.5” (38 mm), 2” (50 mm), 2.5” (64 mm), 3” (75 mm), 3.5” (89 mm) and 4”(100 mm). • Can be precut at the factory to the size you need with IKO AccuCut™ Service. • Enerfoil could work as a Weather-Resistive Barrier (WRB) system for exterior walls. When Enerfoil thicker than 2” (50 mm) is detailed with IKO AquaBarrier™ Tapes (which are primed with IKO S.A.M. Adhesive, IKO S.A.M. Adhesive LVC, or IKO Water-Based Adhesive), the Enerfoil system can be a code-compliant WRB assembly for exterior walls, thus fulfilling two jobs at •

1 Cladding With Strapping Attachment For wood- or metal-framed assemblies, corner bracing is recommended at corners and around large openings. The framing must be structurally rein forced with either cross bracing or structural sheathing. Fasten Enerfoil to wood studs with washered nails. Fasten Enerfoil to steel studs using mechanical fasteners and washers. 2 Cladding with Masonry Ties Fasten Enerfoil to wood studs with washered nails. Fasten Enerfoil to steel studs with washered mechanical fasteners. 3 Block Wall Construction Attach Enerfoil against block wall with air/vapor barrier. Cut boards to friction fit between building code-approved ma sonry ties. 4 Direct Attachment of Cladding Framing must be structurally reinforced with either cross bracing or structural sheath ing. Install Enerfoil and butt all edges. Secure boards with washered fasteners. Install new siding according to manufac turer’s instructions. 5 Interior Ceiling & Wall Applications When used in interior ceiling and wall applications, Enerfoil must be protected from the building interior by a minimum 1/2” (12 mm) gypsum board. The use of an interior vapor retarder may not be required if the seams are taped. Consult your local building code. For walls, install Enerfoil with edges in direct contact with the framing members.

Batt Insulation

Enerfoil Insulation Siding Vapor Control Layer Drywall

1

Structural Sheathing – Wood

AquaBarrier VP

S.A.M. Adhesive

Strapping – Wood

Air Space 1” (25 mm)

AquaBarrier TWF

Drywall

Batt Insulation

2

Vapor Control Layer

Structural Sheathing – Wood

Enerfoil Insulation Masonry Ties AquaBarrier Mastic

AquaBarrier VP

S.A.M. Adhesive

Brick

Air Space 1” (25 mm)

AquaBarrier TWF

CMU block

3

Masonry Ties

AquaBarrier Mastic

AquaBarrier VP

Enerfoil Insulation

S.A.M. Adhesive

Brick Veneer

Air Space 1” (25 mm)

Weep Holes

AquaBarrier TWF

Enerfoil Insulation Siding Vapor Control Layer Drywall Structural Sheathing – Wood

4

Batt Insulation AquaBarrier AVB

once and eliminating the need for a building wrap and a vapor barrier.

S.A.M. Adhesive

Air Space 1” (25 mm)

AquaBarrier TWF

Codes & Compliances ASTM E84 Flame Spread Index < 75 Smoke Density Index < 450 CAN/ULC S102 Flame Spread Index (Canada) < 500

Batt Insulation

5

Drywall

Enerfoil Insulation

ASTM C1289 CAN/ULC S704

CAN/ULC S742 Class A1

CCMC#

Enerfoil Insulation

Drywall

Type 1 Class 1

13188-L

Batt Insulation

AquaBarrier Tape

Nominal Thickness 4 x 8 Boards

R-Value

1/2"

3.1

FOIL4812 FOIL481 FOIL482 FOIL483

1"

6.2

Scan for More Info

2"

12.4

3”

18.6